Hioki Indonesia - MEMORY HiCORDER MR8740T The MR8740T (MR8740-50) is rack-mountable data acquisition system that delivers high-speed, multi...
Hioki Indonesia - MEMORY HiCORDER MR8740T
The MR8740T (MR8740-50) is rack-mountable data acquisition system that delivers high-speed, multi-channel measurements over maximum of 108 channels. Generate simulated signals and record at the same time using plug-and-play input units, making the waveform recorder ideal for evaluating multi-signal devices such as vehicle electronic control units (ECU).
Key Features• Ideal for multipoint inspection of high performance boards such as ECU
• 108ch analog to 96ch analog + 48ch logic input
• Reduce time required to save to external media to max.1/100 compared with conventional method
• 20 MS/s simultaneous sampling on all channels
• Safe measurement with all analog inputs isolated
• Supports 4K monitor to display multi-channel waveforms without overlapping
• Measure 4 channels with 1 unit (4 ch analog Unit U8975, 4 ch DVM Unit U8991)
• Generate constant voltage, constant current, and simulated resistance (VIR Generator Unit U8794)
Basic specifications
Number of input units | Max. 27 slots |
---|---|
Number of channels | [Using the U8975] Max. 108 ch analog, or 96 ch analog + 48 ch logic (when used in combination with U8975 + 8973) [Using the 8966] Max. 54 ch analog, or 48 ch analog + 48 ch logic (when used in combination with 8966 + 8973) *Logic unit 8973 is limited to slots 25 to 27, up to 3 units. *Analog unit channels are isolated from each other and from chassis. Logic unit channels share a common GND with chassis. |
Measurement ranges | 100 mV to 400 V f.s., 12 ranges, resolution : 1/2000 of range (when using 8966) 4 V to 200 V f.s., 6 ranges, resolution : 1/32000 of range (when using U8975) 100 mV to 1000 V f.s., 5 ranges, resolution : 1/1000 000 of range (when using MR8990) 1 V, 10 V, 100 V f.s., 3 ranges, resolution : 1/1000 000 of range (when using U8991) |
Max. allowable input | 400 V DC (when using 8966; upper limit voltage that can be applied between input terminals without damage) |
Max. rated voltage to earth | 300 V AC/DC (input and instrument are isolated; between input channels and chassis; upper limit voltage that can be applied between input channels without damage) |
Frequency characteristics | DC to 5 MHz (-3 dB, when using 8966) |
Max. sampling speed | 20 MS/s, all ch simultaneous, external sampling: 10 MS/s |
Measurement functions | Memory (high-speed recording) |
Memory capacity | Total of 1 G Word installed, 16 MW/ch (when using 8966), 8 MW/ch (when using U8975 or MR8990), 4 MW/ch (when using U8991) |
Internal storage | SSD 480 GB |
Removable storage | USB memory stick ×8 |
Monitor output | VGA, HDMI, Display Port, Recommended resolution 1920 × 1080 dot or more |
External interfaces | [LAN] 1000 BASE-T, 100 BASE-TX, 10 BASE-TX (2 port) (DHCP and DNS support, FTP server/cliant, HTTP server) [USB] USB 3.0 Series A receptacle × 4, USB 2.0 ×4 |
Power supply | 100 to 240 V AC, 50/60 Hz (400 VA max.) |
Dimensions and mass | 426 mm (16.77 in)W × 177 mm (6.97 in)H × 505 mm (19.88 in)D, 14.0 kg (493.8 oz) (main unit only) |
Accessories | Power cord ×1,Quick Start Manual (booklet) ×1, Instruction Manual (detailed edition) (CD-R) ×1, application disk (CD-R) ×1, blank panel (blank slot only), rack installation hardware |